logo Multitronic Oy
Mjölnaregatan 10
65100 Vasa
Web: www.multitronic.fi
Telefon: 06 - 319 77 00
E-post: info@multitronic.fi

RkPDU Mtrd 2U 32A 230V 36 C13

Tillverkare: APC
ID: AP8853
120390€ Visa Moms 0% Visa Moms 25,5%
Beräknad leverans: Ingen leverans information
4st tillgängliga hos importören
Välj din butik
Inte tillgänglig Öppet idag: 10:00 - 18:00 Information om butiken
Inte tillgänglig Öppet idag: 09:00 - 17:00 Information om butiken
Inte tillgänglig Öppet idag: 10:00 - 17:00 Information om butiken
Inte tillgänglig Öppet idag: 10:00 - 18:00 Information om butiken
Inte tillgänglig Öppet idag: 10:00 - 17:00 Information om butiken
Multitronic Vasa
Multitronic Jakobstad
Multitronic Jyväskylä
Multitronic Villmanstrand
Multitronic Mariehamn
Produktspecifikation
Beskrivning
På lager i butiker
Leverans
Prisutveckling
Anslutningar
Anslutningsdetaljer utgång36x IEC 320 C13
6x IEC 320 C19
Anslutningsdetaljer ingångIEC 309 32A 2P+E
Antal uttag AC42 AC-utgångar
UttagIEC309
AC försäljningsställenC13 coupler, C19 coupler
Vikt & dimension
Vikt6,93 kg
Höjd1791 mm
Bredd56 mm
Djup44 mm
Strömtillförsel
Utspänning (Volt)230 V
Maximal sammanlagd strömförbrukning per fas32 A
Maximal strömförbrukning per fas32 A
Belastningskapacitet7680 VA
Maximal styrka7680 W
Växelström Frekvens50 - 60 hz
Miljökrav
Intervall för relativ operativ luftfuktighet5 - 95%
Temperaturintervall (förvaring)-25 - 65 ° C
Temperatur vid drift5 - 45 ° C
Fuktighet (förvaring)5 - 95%
Certifikat
CertifieringRoHS, REACH
IEC 60950,VDE
Management features
ÖvervakningStrömstyrka, Energiljus, Spänning
Design
ModellEnfas
Produktens färgSvart
MontageVågrät
Rackkapacitet0U
PDU typerMätt
Egenskaper
Kabellängd3 m
Logistikdata
Totalt koldioxidavtryck (kg of CO2e)28921,23
EAN731304277019
Garanti1 år
Source: Icecat.biz

APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (36) C13 & (6) C19, and the cable length is 3m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Multitronic Vasa: 0 st
Beräknad leverans: Ingen leverans information
Multitronic Jakobstad: 0 st
Beräknad leverans: Ingen leverans information
Multitronic Jyväskylä: 0 st
Beräknad leverans: Ingen leverans information
Multitronic Villmanstrand: 0 st
Beräknad leverans: Ingen leverans information
Multitronic Mariehamn: 0 st
Beräknad leverans: Ingen leverans information
Avhämtning från butiken
Beräknad leveranstid: Ingen leverans information
Gratis
Matkahuolto: Paketautomater och serviceställen
Beräknad leveranstid: Ingen leverans information
3,90 €
Posti: Paketautomater och serviceställen
Beräknad leveranstid: Ingen leverans information
4,90 €
Posti: Postpaket
Beräknad leveranstid: Ingen leverans information
4,90 €
Posti: Till dörren-paket
Beräknad leveranstid: Ingen leverans information
6,90 €
Posti: Hempaket
Beräknad leveranstid: Ingen leverans information
16,90 €
De tekniska uppgifterna ovan är endast avsedda som referens och kan ändras. Vi förbehåller oss rätten att korrigera tryckfel och att använda illustrationer som vägledning. Viss text kan vara autogenererad eller maskinöversatt, vilket kan leda till felaktigheter.

Startsida

Meny

Köpkorg

Sökning