Anslutningar | |
Antal uttag AC | 4 AC-utgångar |
Antalet output IEC jumpers | 2 |
Uttag | C14 coupler |
AC försäljningsställen | C13 coupler |
USB-port | |
Vikt & dimension | |
Vikt | 28,6 kg |
Vikt inkl. förpackning | 31,9 kg |
Höjd | 251 mm |
Bredd | 432 mm |
Djup | 457 mm |
Låddjup | 603 mm |
Förpackningens bredd | 594 mm |
Miljökrav | |
Altitud vid drift | 0 - 3000 m |
Intervall för relativ operativ luftfuktighet | 0 - 95% |
Temperaturintervall (förvaring) | -15 - 45 ° C |
Temperatur vid drift | 0 - 40 ° C |
Fuktighet (förvaring) | 0 - 95% |
Höjd över havet i avstängt läge | 0 - 15000 m |
Förpackning | |
Kabel inkluderad | USB-kabel |
Snabbinstallationsguide | |
CD med programvara | |
Rackmonteringssats | |
Batteri | |
Batteriteknik | Slutna blybatterier (VRLA) |
Laddningstid | 3 h |
Normal drifttid vid halv belastning | 18,7 min |
Normal drifttid vid full belastning | 6,8 min |
Hot-swap batteri | |
Kallstart | |
Automatiskt batteritest | |
Batterikapacitet | 260 VAh |
Batteriets livslängd (max) | 6 År |
Design | |
Certifiering | CSA, NOM, UL 1778, REACH |
Formfaktor | Rackmonterad |
Indikationer | |
Produktens färg | Svart |
Rackkapacitet | 2U |
Skärmtyp | LCD |
Egenskaper | |
Hörbart larm | |
Energivärdering | 459 J |
Ljudnivå Lc IEC | 46 dB |
Ingångsfrekvens | 50/60 hz |
Inmatning spänning (max) | 300 V |
Inmatning spänning (min) | 170 V |
Vågform | Sinus |
Utgångsfrekvensreglering | 57 - 63 hz |
Automatisk spänningsreglering (AVR) | |
Automatisk omstart | |
UPS-topologi | Linjeinteraktiv |
Hålltid (max) | 2 ms |
Logistikdata | |
Produkter per lastpall | 16 styck |
EAN | 0731304303718 |
Garanti | 2 år |
Source: Icecat.biz |
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
LCD Status Display
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
High online efficiency
Reduces utlility costs, generates less heat.
Cold-start capable
Provides temporary battery power when the utility power is out.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Network manageable
Provides remote power management of the UPS over the network.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial Connectivity
Provides management of the UPS via a serial port.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Beräknad leverans: 16.04 - 19.04
Idag: Stängt (Långfredagen)
Beräknad leverans: 16.04 - 19.04
Idag: Stängt (Långfredagen)
Beräknad leverans: 16.04 - 19.04
Idag: Stängt (Långfredagen)
Beräknad leverans: 16.04 - 19.04
Idag: Stängt (Långfredagen)
Beräknad leverans: 16.04 - 19.04
Idag: Stängt
Beräknad leverans: 16.04 - 19.04
Idag: Stängt (Långfredagen)
Beräknad leverans: 16.04 - 19.04
Idag: Stängt (Långfredagen)
Beräknad leveranstid: 16.04 - 19.04
Beräknad leveranstid: 17.04 - 19.04
Beräknad leveranstid: 16.04 - 18.04
Beräknad leveranstid: 17.04 - 19.04
Beräknad leveranstid: 17.04 - 18.04
Beräknad leveranstid: 17.04 - 18.04