APC InRow RC ACRC301H - Ilmastointilaitteen jäähdytysjärjestelmän viileä vesi - musta - 42U
Valmistaja: APC
ID: ACRC301H
1636890€
Näytä ALV 0%
Näytä ALV 25,5%
Multitronic Vaasa
Multitronic Pietarsaari
Multitronic Jyväskylä
Multitronic Lappeenranta
Multitronic Maarianhamina
Tuotetiedot
Kuvaus
Myymäläsaatavuus
Toimitus
Hinnan muutokset
Manuals
| Paino ja mitat | |
| Paino | 210 kg |
| Tuotteen korkeus | 1991 mm |
| Tuotteen leveys | 300 mm |
| Tuotteen syvyys | 1095 mm |
| Pakkaustiedot | |
| Pakkauksen paino | 220 kg |
| Pakkauksen syvyys | 1137 mm |
| Pakkauksen korkeus | 2118 mm |
| Pakkauksen leveys | 746 mm |
| Ominaisuudet | |
| Tuotteen väri | Musta |
| EAN | 0731304301370 |
| Takuu | 1 vuosi |
| Source: Icecat.biz | |
Active Airflow Control
Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
Dew point monitoring
Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.
Hot swappable fans
Allows system to remain operational if a fan replacement is required.
Leak detection
Notifies user in the event of a water leak within the coiling unit.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Washable filters
Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
InRow Chilled Water CoolingFeatures & Benefits
Availability
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Serviceability
Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Agility
Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Casters
Provides flexibility to move the unit to wherever cooling is required.
Manageability
Real-Time Capacity Monitoring
Real-time display of current and available cooling.
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Total Cost of Ownership
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
Dew point monitoring
Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.
Hot swappable fans
Allows system to remain operational if a fan replacement is required.
Leak detection
Notifies user in the event of a water leak within the coiling unit.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Washable filters
Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
InRow Chilled Water CoolingFeatures & Benefits
Availability
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Serviceability
Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Agility
Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Casters
Provides flexibility to move the unit to wherever cooling is required.
Manageability
Real-Time Capacity Monitoring
Real-time display of current and available cooling.
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Total Cost of Ownership
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Multitronic Vaasa: 0 kpl
Arvioitu toimitus: 21.11. - 24.11.
Arvioitu toimitus: 21.11. - 24.11.
Tänään: Suljettu
Multitronic Pietarsaari: 0 kpl
Arvioitu toimitus: 21.11. - 24.11.
Arvioitu toimitus: 21.11. - 24.11.
Tänään: Suljettu
Multitronic Jyväskylä: 0 kpl
Arvioitu toimitus: 21.11. - 24.11.
Arvioitu toimitus: 21.11. - 24.11.
Tänään: Suljettu
Multitronic Lappeenranta: 0 kpl
Arvioitu toimitus: 21.11. - 24.11.
Arvioitu toimitus: 21.11. - 24.11.
Tänään: Suljettu
Multitronic Maarianhamina: 0 kpl
Arvioitu toimitus: 21.11. - 24.11.
Arvioitu toimitus: 21.11. - 24.11.
Tänään: Suljettu
Nouto myymälästä
Arvioitu toimitusaika: 21.11. - 24.11.
Arvioitu toimitusaika: 21.11. - 24.11.
Posti: Ovelle-paketti
Arvioitu toimitusaika: 22.11. - 23.11.
Arvioitu toimitusaika: 22.11. - 23.11.
Posti: Kotipaketti
Arvioitu toimitusaika: 22.11. - 23.11.
Arvioitu toimitusaika: 22.11. - 23.11.
- manual pdf (English)
- leaflet (English)
Edellä mainitut tekniset tiedot ovat vain viitteellisiä, ja ne voivat muuttua ilman ennakkoilmoitusta. Pidätämme oikeuden korjata virheet ja käyttää kuvia ohjeellisina. Teksti voi sisältää automaattisesti luotuja tai koneellisesti käännettyjä osia, mikä saattaa aiheuttaa epätarkkuuksia.