logo Multitronic Oy
Mjölnaregatan 10
65100 Vasa
Web: www.multitronic.fi
Telefon: 06 - 319 77 00
E-post: info@multitronic.fi

10 SLOT CHASSIS NO POWER

Tillverkare: CISCO
ID: N7K-C7010=
Produkten är inte tillgänglig
Produkten har utgått från sortimentet eller är inte tillgänglig för tillfället.
Produktspecifikation
Beskrivning
På lager i butiker
Leverans
Prisutveckling
Tekniska data
Produktens färgSvart
Värmeavgivning12000 BTU/h
Rackkapacitet21U
Nödvändig programvaraCisco NX-OS 4.0
Anslutningar
Expansionsplatser10
Vikt & dimension
Vikt90 kg
Höjd933 mm
Bredd439 mm
Djup841 mm
Miljökrav
Altitud vid drift0 - 2000 m
Intervall för relativ operativ luftfuktighet5 - 95%
Temperaturintervall (förvaring)-40 - 70 ° C
Temperatur vid drift0 - 40 ° C
Fuktighet (förvaring)5 - 95%
Certifikat
SäkerhetUL/CSA/IEC/EN 60950-1, AS/NZS 60950
EAN0882658174445
Garanti3 månader
Source: Icecat.biz
Cisco Nexus 7000 Series 10-Slot Chassis

- The Cisco Nexus 7000 Series 10-slot chassis with up to eight I/O module slots supports up to 256 10 Gigabit Ethernet or 384 Gigabit Ethernet ports, meeting the demands of large deployments.
- Front-to-back airflow helps ensure that use of the Cisco Nexus 7000 Series 10-slot chassis addresses the requirement for hot-aisle and cold-aisle deployments without additional complexity.
- The system uses dual system and fabric fan trays for cooling. Each fan tray is redundant and composed of independent variable-speed fans that automatically adjust to the ambient temperature, helping reduce power consumption in well-managed facilities while providing optimum operation of the switch. The system design increases cooling efficiency and provides redundancy capabilities, allowing hot swapping without affecting the system; if either a single fan or a complete fan tray fails, the system continues to operate without a significant degradation in cooling capacity.
- The integrated cable management system is designed for fully configured systems cabling to be groomed either to a single side or to both sides for maximum flexibility without obstructing any important components, which eases maintenance even when the system is fully cabled.
- The system supports an optional air filter to help ensure clean air flow through the system. The addition of the air filter satisfies Network Equipment Building Standards (NEBS) requirements.
- A series of LEDs at the top of the chassis provides a clear summary of the status of the major system components, alerting operators to the need to conduct further investigation. These LEDs report the power supply, fan, fabric, supervisor, and I/O module status.
- The cable management cover and optional front module doors provide protection from accidental interference with both the cabling and modules installed in the system. The transparent front door allows observation of cabling and module indicator and status lights.

Ingen prisutvecklingsinformation för denna produkt.

Multitronic Vasa: 0 st
Beräknad leverans: Ingen leverans information
Multitronic Jakobstad: 0 st
Beräknad leverans: Ingen leverans information
Multitronic Jyväskylä: 0 st
Beräknad leverans: Ingen leverans information
Multitronic Villmanstrand: 0 st
Beräknad leverans: Ingen leverans information
Multitronic Mariehamn: 0 st
Beräknad leverans: Ingen leverans information
De tekniska uppgifterna ovan är endast avsedda som referens och kan ändras. Vi förbehåller oss rätten att korrigera tryckfel och att använda illustrationer som vägledning. Viss text kan vara autogenererad eller maskinöversatt, vilket kan leda till felaktigheter.