HPE E6600-24G-4XG Data center. 24x 10/100/1000Base-T -porttia joista 4 kpl MInigbic comboja + 4 kpl SFP+ 10 GbE porttia.. Yksi poweri ja yksi vapaa RPS-paikka.

Manufacturer: HEWLETT-PACKARD
ID: J9264A#ABB
Product unavailable
This product is end of life or currently not available.
Specifications
Description
Store availability
Delivery
Price development
Ports & interfaces
Console portRS-232
Basic switching RJ-45 Ethernet ports quantity24
Weight & dimensions
Weight7.8 kg
Energy management
Power consumption (typical)204.3 W
Input voltage100-120 / 200-240 VAC
Operational conditions
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)41 - 104 °F
Protocols
Supported network protocolsRFC 1591 DNS (client); HTML and telnet management; IEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP; RFC 4675 RADIUS VLAN & Priority; RFC 3376 IGMPv3 (host joins only); RFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License); RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication;
RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4443 ICMPv6;
RFC 4541 IGMP & MLD Snooping Switch; RFC 4861 IPv6 Neighbor Discovery; RFC 4862 IPv6 Stateless Address Auto-configuration; RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB; RFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA; RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF); IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting.
Networking
Full duplexcheckmark
Flow control supportcheckmark
Link aggregationcheckmark
DHCP clientcheckmark
IGMP snoopingcheckmark
Data transmission
MAC address table10000 entries
Maximum data transfer rate1 Gbit/s
Throughputup to 75.7 million pps (64-byte packets)
Management features
Switch typeManaged network switch
Other features
Dimensions (WxDxH)546.1 x 442.5 x 43.2 mm
Electromagnetic immunityEN 55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3
I/O ports20 auto-sensing 10/100/1000 ports(IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T), Media Type: Auto-MDIX, Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only; 4 dual-personality ports, each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers); 4 SFP+ 10-GbE ports, Duplex: full only; 1 RS-232C DB-9 console port
Latency1000 Mb Latency: < 3.4 µs (FIFO 64-byte packets); 10 Gbps Latency: < 2.4 µs (FIFO 64-byte packets)
Remote administrationcommand-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Power supply type1 x J9269A
Management platformHP PCM+; HP PCM (included); command-line interface; Web browser; configuration menu
Memory and processor: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, packet buffer size: 36 MB QDR SDRAM total (18 MB for 1-GbE & 10-GbE ports), 256 MB compact flash, 256 MB DDR SDRAM
Power requirements100 -120 VAC / 200 -240 VAC; 50 /60 Hz.
The switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz
Electromagnetic emissionsFCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A.
Supported protocolsRFC 1591 DNS (client); HTML and telnet management
RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB
MIBs
IP multicast
IEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP (Premium License); RFC 4675 RADIUS VLAN & Priority
RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2461 IPv6 Neighbor Discovery; RFC 2462 IPv6 Stateless Address Auto-configuration; RFC 2463 ICMPv6; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4541 IGMP & MLD Snooping Switch
IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON
Network management
General protocols
Security
IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv2 Secure Shell
IPv6
Device management
OSPF
RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF)
RFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA
RFC 3376 IGMPv3 (host joins only); RFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
Connectivity technologyWired
MountingTelco rack: Mounts in an EIA-standard 19-in. 2-post telco rack or equipment cabinet; horizontal surface mounting only. Rack kit: Rack rails are required for mounting in HP 10000 Series 4-post racks.
Input frequency50 / 60
Electrical enhancementsThe switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz
Weight (imperial)17.2 lb.
Acoustic noise noteISO 7779, ISO 9296
Heat dissipation note(max. non-PoE); 940 BTU/hr (991 kJ/hr) (max. using PoE)
Management product nameHP ProCurve Manager Plus; HP ProCurve Manager (included)
Operating altitude (imperial)up to 10000 ft.
Power supply slots open2
Switch fabric speed105.6 Gbps
Fan tray slots1
Fan trays1 x J9271A
Design
SafetyCSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950
Electromagnetic compatibilityFCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Power over Ethernet (PoE)
Power over Ethernet (PoE)cross
Performance
Processor frequency666 MHz
Internal memory256 MB
Flash memory256 MB
Stackablecheckmark
Built-in processorPowerPC 8540
EAN884420075912
Warranty1 year
Source: Icecat.biz

The HP ProCurve 6600 Switch Series consists of the most advanced data center server edge switches in the HP ProCurve Networking product line. The 6600 series includes 1U 10/100/1000Base-T and 10-GbE SFP+ stackables enhanced for server edge connectivity with front-to-back cooling, redundant hot-swappable power, and redundant hot-swappable fans. The foundation for all of these switches is a purpose-built, programmable ProVision ASIC that allows the most demanding networking features, such as Quality of Service (QoS) and security, to be implemented in a scalable yet granular fashion. With a variety of connectivity interfaces and expanded buffering, the 6600 switches offer excellent investment protection, flexibility, and scalability, as well as ease of deployment and reduced operational expense.

No price development information for this product.

Multitronic warehouse store: 0 pcs
Estimated delivery: Unknown
Multitronic | JNT Pietarsaari: 0 pcs
Estimated delivery: Unknown
Multitronic Seinäjoki: 0 pcs
Estimated delivery: Unknown
Multitronic | iTronic Jyväskylä: 0 pcs
Estimated delivery: Unknown
Multitronic | iTronic Lappeenranta: 0 pcs
Estimated delivery: Unknown
Multitronic Mariehamn: 0 pcs
Estimated delivery: Unknown
iTronic Vaasa: 0 pcs
Estimated delivery: Unknown

Main page

Menu

Cart

Search