| Technical details | |
| Certification | FCC Part 15, Class A, CE, NEMA TS2, UL Class 1, Division 2, Groups A, B, C, D |
| Serial interface type | RS-232/422/485 |
| Serial ports quantity | 1 |
| Data transfer rate | 0.234 Mbit/s |
| Networking standards | IEEE 802.3 |
| Flow control support | ![]() |
| Auto MDI/MDI-X | ![]() |
| RS-232 signals | CTS, DCD, DSR, DTR, GND, RTS, RXD, TXD |
| Baud rate | 230400 Kbit/s |
| RS-422 signals | GND |
| RS-485 signals | Data+, Data-, GND |
| Data bits | 5, 6, 7, 8 |
| Stop bits | 1, 1.5, 2 |
| Ports & interfaces | |
| Cabling technology | 10/100Base-T(X) |
| Ethernet LAN (RJ-45) ports | 1 |
| Weight & dimensions | |
| Dimensions (WxDxH) | 81 x 119 x 30 mm |
| Weight | 100 g |
| Energy management | |
| Input voltage | 10 - 58 V |
| Power consumption | 4000 mA |
| Operational conditions | |
| Operating relative humidity (H-H) | 10 - 95% |
| Storage temperature (T-T) | -40 - 85 °C |
| Operating temperature (T-T) | -40 - 80 °C |
| Protocols | |
| Supported network protocols | TCP, IPv4, UDP, ARP, HTTP 1.0, ICMP/PING, DHCP/BOOTP, DHCP,, TCP |
| Illumination/Alarms | |
| LED indicators | ![]() |
| Operating system/software | |
| Windows operating systems supported | Windows 7, Windows Vista, Windows XP Home, Windows XP Home x64, Windows XP Professional, Windows XP Professional x64 |
| Server operating systems supported | Windows Server 2003, Windows Server 2008 |
| Design | |
| Product colour | Black |
| International Protection (IP) code | IP30 |
| EAN | |
| Warranty | 6 months |
| Source: Icecat.biz | |
DETAILS
- UL Listed for use in Class 1 Division 2 hazardous areas.
- NEMA TS-2 rated for use in transportation applications.
- Routes Modbus traffic based on Modbus ID, and remaps conflicting Modbus IDs.
- Offers Modbus messaging priority control, selectable by source or function code.
- Features a built-in Web server and easy-to-use management software.
- Can be easily integrated into most Modbus network configurations.
- Converts ASCII to RTU as well as ASCII or RTU to Modbus TCP.
- Features a DB9 port and terminal block for serial connections.
- Equipped with a 10-/100-Mbps port for TCP connectivity.
- Boasts high throughput with low latency.
- Slim IP30 enclosure saves you on DIN rail space.
- Includes a DIN mounting clip and spring.
Easily integrate an older serial Modbus device into your Ethernet Modbus network. This rugged serial server gives you a simple way to migrate to an Ethernet-based industrial control system—without having to replace the older Modbus equipment you've already invested in. Translating older and newer protocols, the 1-Port Modbus Hardened Serial Server converts mismatched serial baud rates and settings, enabling the serial Modbus device to become a node on your Ethernet network. Older PLCs can then talk to newer sensors, meters, scales, and other industrial monitoring and automation instruments. Configuration can be done through a direct serial connection or via the network, so you can improve productivity and cut down on the amount of time required to troubleshoot a serial device on a factory floor or in a remote location. Configure devices, upgrade firmware, and more—all this from the comfort of your office. A simple-to-install, user-friendly software application enables programming. No time-consuming setup is required. The software also features Modbus messaging priority control and allows management through multiple TCP/IP client sessions. The serial server can be configured for TCP client or server operation. A built-in traffic monitor provides instant verification of a successful installation, and you can view the serial server's operational status in real time. The 1-Port Modbus Hardened Serial Server has a standard DB9 serial port for RS-232 device connections and a removable terminal block for an RS-422 or RS-485 device connection. It also has an autodetecting 10BASE-T/100BASE-TX port for the Ethernet network connection. Either device on either side can be a Modbus master or slave, customizable to your application. A serial master can be configured to control an IP slave, for instance. Also, a serial slave device can be accessed over a LAN or WAN by up to 16 simultaneous Modbus TCP masters.
- UL Listed for use in Class 1 Division 2 hazardous areas.
- NEMA TS-2 rated for use in transportation applications.
- Routes Modbus traffic based on Modbus ID, and remaps conflicting Modbus IDs.
- Offers Modbus messaging priority control, selectable by source or function code.
- Features a built-in Web server and easy-to-use management software.
- Can be easily integrated into most Modbus network configurations.
- Converts ASCII to RTU as well as ASCII or RTU to Modbus TCP.
- Features a DB9 port and terminal block for serial connections.
- Equipped with a 10-/100-Mbps port for TCP connectivity.
- Boasts high throughput with low latency.
- Slim IP30 enclosure saves you on DIN rail space.
- Includes a DIN mounting clip and spring.
Easily integrate an older serial Modbus device into your Ethernet Modbus network. This rugged serial server gives you a simple way to migrate to an Ethernet-based industrial control system—without having to replace the older Modbus equipment you've already invested in. Translating older and newer protocols, the 1-Port Modbus Hardened Serial Server converts mismatched serial baud rates and settings, enabling the serial Modbus device to become a node on your Ethernet network. Older PLCs can then talk to newer sensors, meters, scales, and other industrial monitoring and automation instruments. Configuration can be done through a direct serial connection or via the network, so you can improve productivity and cut down on the amount of time required to troubleshoot a serial device on a factory floor or in a remote location. Configure devices, upgrade firmware, and more—all this from the comfort of your office. A simple-to-install, user-friendly software application enables programming. No time-consuming setup is required. The software also features Modbus messaging priority control and allows management through multiple TCP/IP client sessions. The serial server can be configured for TCP client or server operation. A built-in traffic monitor provides instant verification of a successful installation, and you can view the serial server's operational status in real time. The 1-Port Modbus Hardened Serial Server has a standard DB9 serial port for RS-232 device connections and a removable terminal block for an RS-422 or RS-485 device connection. It also has an autodetecting 10BASE-T/100BASE-TX port for the Ethernet network connection. Either device on either side can be a Modbus master or slave, customizable to your application. A serial master can be configured to control an IP slave, for instance. Also, a serial slave device can be accessed over a LAN or WAN by up to 16 simultaneous Modbus TCP masters.
Multitronic Vaasa: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: Closed
Multitronic Pietarsaari: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: Closed
Multitronic Jyväskylä: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: Closed
Multitronic Lappeenranta: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: Closed
Multitronic Mariehamn: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: Closed
Fetch from the shop
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Posti: Parcel lockers and service points
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Posti: Postal package
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Matkahuolto: Parcel lockers and service points
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Posti: Doorstep delivery
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Matkahuolto: Business Parcel
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Matkahuolto: Home Parcel
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Posti: Home delivery
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
- leaflet (English)
- manual pdf (English)
The above technical details are for reference only and may change without notice. We reserve the right to correct printing errors and use illustrations for guidance. Some text may be auto-generated or machine-translated, which could lead to inaccuracies.