Specifications
Description
Store availability
Delivery
Price development
Manuals
| Ports & interfaces | |
| USB 2.0 ports quantity | 1 |
| Modem (RJ-11) ports | 1 |
| Ethernet LAN (RJ-45) ports | 1 |
| AC outlet types | Type E |
| SmartSlot | ![]() |
| Weight & dimensions | |
| Weight | 10.4 kg |
| Height | 250 mm |
| Width | 100 mm |
| Depth | 382 mm |
| Operational conditions | |
| Operating altitude | 0 - 3000 m |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage temperature (T-T) | -5 - 45 °C |
| Operating temperature (T-T) | 0 - 40 °C |
| Storage relative humidity (H-H) | 0 - 95% |
| Non-operating altitude | 0 - 15000 m |
| Packaging data | |
| Package weight | 12.7 kg |
| Packaging content | |
| Management card included | ![]() |
| Battery | |
| Battery technology | Sealed Lead Acid (VRLA) |
| Battery recharge time | 8 h |
| Replacement battery cartridge | 1 |
| Other features | |
| Interface | USB |
| Package dimensions (WxDxH) | 229 x 483 x 381 mm |
| Battery type | APCRBC123 |
| Networking features | 10/100/1000 Base-T |
| Nominal output voltage | 230 V |
| Filtering description | UL 1449 |
| Nominal input voltage | 230 V |
| Design | |
| Cable length | 1.52 m |
| Product colour | Black |
| Features | |
| Audible alarm(s) | ![]() |
| Output power capacity | 0.9 kVA |
| Surge energy rating | 355 J |
| Noise level | 45 dB |
| Output power | 540 W |
| Logistics data | |
| Harmonized System (HS) code | 85078000 |
| EAN | 5711045416026 |
| Warranty | 2 years |
| Source: Icecat.biz | |
The Back-UPS RS offers high performance protection for your business and office computer systems. It provides abundant battery backup power, allowing you to work through medium and extended length power outages. It also safeguards your equipment from damaging surges and spikes that travel along utility, phone and network lines. A distinguishing feature of the Back-UPS RS is automatic voltage regulation (AVR). AVR instantly adjusts both low and high voltages to safe levels, so you can work indefinitely during brownouts and overvoltage situations, saving the battery for power outages when you need it most. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and plentiful outlets (including transformer-block spaced outlets) make the Back-UPS RS the perfect unit to protect your business' productivity from the constant threat of power problems and lost data.
BR900G-FR Features:
Power-saving outlets
Automatically cuts power to idle equipment to conserve electricity.
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Audible alarms
Provides notification of changing utility power and UPS conditions.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery replacement without tools
Allows quick, easy battery replacement.
LED status indicators
Quickly understand unit and power status with visual indicators.
Cold-start capable
Provides temporary battery power when the utility power is out.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Resettable circuit breakers
Enables a quick recovery from overload events.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Manageability:
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Intelligent battery management
Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.
BR900G-FR Features:
Power-saving outlets
Automatically cuts power to idle equipment to conserve electricity.
Boost Automatic Voltage Regulation (AVR)
Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Audible alarms
Provides notification of changing utility power and UPS conditions.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery replacement without tools
Allows quick, easy battery replacement.
LED status indicators
Quickly understand unit and power status with visual indicators.
Cold-start capable
Provides temporary battery power when the utility power is out.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Resettable circuit breakers
Enables a quick recovery from overload events.
Transformer-block spaced outlets
Protect equipment with input transformer blocks without blocking access to other receptacles.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Manageability:
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Intelligent battery management
Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.
Multitronic Vaasa: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: 10:00 - 18:00
Multitronic Pietarsaari: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: 09:00 - 17:00
Multitronic Jyväskylä: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: 10:00 - 17:00
Multitronic Lappeenranta: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: 10:00 - 18:00
Multitronic Mariehamn: 0 pcs
Estimated delivery: No delivery date yet
Estimated delivery: No delivery date yet
Today: 10:00 - 17:00
Fetch from the shop
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Posti: Parcel lockers and service points
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Posti: Postal package
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Posti: Doorstep delivery
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Matkahuolto: Business Parcel
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Matkahuolto: Home Parcel
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
Posti: Home delivery
Estimated delivery time: No delivery date yet
Estimated delivery time: No delivery date yet
- manual pdf (English)
The above technical details are for reference only and may change without notice. We reserve the right to correct printing errors and use illustrations for guidance. Some text may be auto-generated or machine-translated, which could lead to inaccuracies.